High Frequency Spinal Cord Stimulation (HF-SCS) in a Sub-Acute Animal Model of Spinal Cord Injury (SCI)
Palabras clave:
High frequency spinal cord stimulation, animal model, spinal cord injuryResumen
Introduction: In previous studies, HF-SCS applied at the T2 spinal level was shown to result in physiologic activation of the both the diaphragm and inspiratory intercostal muscles in C2 spinal sectioned dogs. While the bulbo-spinal fibers were cut, they likely survived given the short duration of the day long acute experiments and that the mechanism of inspiratory muscle activation may have involved stimulation of these fibers. Since these fibers would not be viable in patients with chronic ventilator dependent SCI.
Objective: To determine if HF-SCS is effective following degeneration of these fibers.
Material and Methods: In 2 anesthetized, C2 paralyzed, intubated and mechanically ventilated dogs, an electrode lead was positioned on the ventral epidural surface of the spinal cord at the T2 level to activate the inspiratory muscles. Animal temperature, end-tidal PCO2 and oxygen saturation were continuously monitored. The effectiveness of HF-SCS in generating inspired volume (V) and negative airway pressures (P) was evaluated over a period of 5 days during which time the bulbo-spinal fibers would have degenerated. Since the effectiveness of HF-SCS may be adversely affected by deterioration in the condition of the animal, low frequency (50Hz) SCS (LF-SCS) was also performed and served as a control.
Results: All vital signs, oxygen saturation and end-tidal PCO2 remained stable over the 5-day period. V and P also remained stable over the study period. For example, V and P were 771±25ml and 64±1cmH2O with HF-SCS (3mA, 300Hz) during the initial and 674±59ml and 63±5cmH2O and final 6 hours on day 5. Comparable values during LF-SCS (8mA, 50Hz) were 467±12ml and 48±1cmH2O during the initial and 397±16ml and 40±1cmH2O final 6 hours on day 5.
Conclusions: Since V and P in response to HF-SCS remained stable over a 5-day period following which the bulbo-spinal fibers would have degenerated, the mechanism of HF-SCS does not depend upon the viability of these tracts. HF-SCS therefore may be a useful method to restore ventilation in ventilator dependent tetraplegicsDescargas
Descargas
Publicado
Cómo citar
Número
Sección
Licencia
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes: Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons (CC-BY-NC 4.0) que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista. Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista. Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).
Como Revista Cubana de Investigaciones Biomédicas forma parte de la red SciELO, una vez los artículos sean aceptados para entrar al proceso editorial (revisión), estos pueden ser depositados por parte de los autores, si estan de acuerdo, en SciELO preprints, siendo actualizados por los autores al concluir el proceso de revisión y las pruebas de maquetación.