Technique of skin free flaps pedicled transfer in the rat
Keywords:
microcirugía, transferencia libre de piel, rata de laboratorio, anastomosis vasculares, cirugía experimental, entrenamiento microquirúrgico, gafalupas binocularesAbstract
Introduction: Experimental model of free flaps of skin in the rat has a great acceptance in microsurgical training programs, and it has demonstrated to be a practical tool.
Objective: To describe the technique in an experimental model of free skin flaps in the rat that is included in the program of microsurgical training of advanced techniques in the Center of Experimental Surgery.
Methods: Five Wistar male rats with a weight of 350 g, supplied by National Center of Laboratory Animals Production (CENPALAB) and anesthetized with Sodium Tiopental (60 mg / Kg corporal weight) for intraperitoneal via. Technique that we used consisted in tying femoral vessels distally; inmediatly from behind to superficial epigastric vessels and cut more proximal to femoral vessels (terminal ends of pedicle) what is obtained a bigger caliber that facilitates the anastomosis with the receptors vessels of neck rat.
Results: Connected the superficial epigastric vessels to femoral vessels as terminal ends were possible to carry out the technique with the employment of binocular loupes without the use of operative microscope.
Conclusions: Model of skin free flaps pedicled transfer in rat to the neck of the own animal is an excellent microsurgical exercise that is included in the program of microsurgical training, mainly for specialists and residents of plastic surgery and reconstructive, surgery maxilofacial and neurosurgery specialties.
Downloads
References
Bibliografía
1.- Rodríguez Sosa VM, Rodríguez Sosa R, Corona Miranda B. Historia del Centro de Cirugía Experimental del Instituto de Ciencias Básicas y Preclínicas "Victoria de Girón" Revista Habanera de Ciencias Médicas [internet] 2015; 14(2):134-147 [Consultada 19 de octubre 2020]. Disponible en: http://www.revhabanera.sld.cu/index.php/rhab/article/view/855/732
2.-MacLeod TM, Williams G, Sanders R, Green CJ. Prefabricated skin flaps in a rat model based on a dermal replacement matrix Permacole. The British Association of Plastic Surgeons; 2003, 56: 775–783(N. del T.: En ingles: Publicación electrónica Published by Elsevier, 30 nov., 2003)
3.-Omer Ozkan, O. Koray Coskunfirat, H. Ege Ozgentas,M. Bahadir Dikici. New experimental flap model in the rat: free flow-through epigastric flap. Microsurgery; [internet] 2004; 24:454–8. [Consultada 19 de octubre 2020]Disponible en: https//: doi.org/10.1002/micr.20063
4.- Rodríguez A, Álvarez A, Centeno A, López E, Martelo F. El colgajo epigástrico en rata: Revisión de la técnica quirúrgica como modelo experimental de un colgajo libre. Revista Española de Investigaciones Quirúrgicas. 2006; 9(1): 5-9. (N. del T.: En español: Publicación electrónica, 2006)
5.- Rodríguez Lorenzo A. Desarrollo de un Programa de Entrenamiento Avanzado en Microcirugía Reconstructiva: Estudio Experimental en Rata. Tesis Doctoral. A Coruña.
España. [Internet]. 2010 [Consultada 10 diciembre 2020]; Disponible en: http:hdl.handle.net/2183/7321
6.-Masa Jurado, I. Efecto del inhibidor de la c1 esterasa sobre el daño por isquemia reperfusión. Modelo experimental de colgajo epigástrico en rata. Tesis doctoral. Madrid. España. 2014
7.- López Machado M. Fundamentos anatómicos de la reconstrucción con colgajos en microcirugía. Trabajo de fin de grado de Medicina. Departamento de Anatomía e Histología Humanas. Facultad de Medicina. Universidad de Zaragoza. Pp. 1-34 España, 2015 (N. del T.: En español: Publicación electrónica de la Universidad de Zaragoza, 2015)
8.-Hartle A, Gibb S, Goddard A. Can doctors be trained in a 48 hour working week?
BMJ [Internet]. 2014 [Consultada enero 2021]; 349:g7323. Disponible en:http://
www.ncbi.nlm.nih.gov/pubmed/25498122 (Abstract)
9.-Strauch B, Murray DE. Transfer of composite graft with immediate suture anastomosis of its vascular pedicle measuring less than 1 mm. in external diameter using microsurgical techniques. Plast Reconstr Surg [internet]1967 [Consultada 2 de noviembre 2020] 40:325–9. Disponible en:https//:doi: 10.1097/00006534-196710000-000502.PMID:4863084
10.-Franken R. Microsurgery without a microscopy: laboratory evaluation of three-dimensional on-screen microsurgery. Microsurgery [internet]1995; 6: 746-51.[Consultada 2 de noviembre 2020]. Disponible en: http://pubmed.ncbi.nlm.nih.gov/9148102 (Abstract)
11.- Lee HJ, Lim SY, Pyon JK, Bang SI, Oh KS, Shin MS, Mun GH. The influence of pedicle tension and twist on perforator flap viability in rats. J Reconstr Microsurg, 2011; 277:433–38 (En ingles: Publicación electrónica, 2011)
12. Shenaq S. Free tissue transfer with the aid of loupe magnification: experience with 251 procedures. Plast Recontr Surg [internet]1995; [Consultada 7 de noviembre 2020] 95: 261-9: Disponible en: https//:pubmed.ncbi.nlm.nih.gov/7824605/
13.- Serletti JM, Deuber MA, Guidera PM, Reading G,Herrera HR, Reale VF, et al. Comparison of the operating microscope and loupes for free microvascular tissue transfer. Plast Reconstr Surg[internet] 1995; 95(2): 270-6. Disponible en:https//: pubmed.ncbi.nlm.nih.gov/7824606
14.- AymerichBolaños O. Generalidades de colgajos y su importancia en la relación con la reparación del daño corporal. MedLeg Costa Rica[internet] 2014; [Consultada 7 de noviembre 2020] 31(1): 49-56. Disponible en: http.//www.scielo.sa.cr/scielo.php?script꞊sci_arttext&pid꞊S1409001520114000100005 Lng꞊en
15.-Casal, D., Pais, D., Iria, I., Mota-Silva, E., Almeida, M.A., Alves, et al.: A model of free tissue transfer: The rat epigastric free flap. J Vis Exp [internet] 2017; (119) e55281, Disponible en: https//:jove.com/t/55281
16.-Demir A, Kucuker I, Keles MK, Demirtas Y. The effect of learning curve on flap selection, re-exploration, and salvage rates in free flaps; a retrospective analysis of 155 cases. Microsurgery [internet] 2013; 33(7): 519-26Disponible en:doi.org/10.1002/micr.22153
17.-Siemionow MZ. Plastic and Reconstructive Surgery: Experimental models and research designs. Springer –Verlag Editor;. pp. 3–67. Ch. 1-7,2015
Downloads
Published
How to Cite
Issue
Section
License
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes: Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons (CC-BY-NC 4.0) que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista. Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista. Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).
Como Revista Cubana de Investigaciones Biomédicas forma parte de la red SciELO, una vez los artículos sean aceptados para entrar al proceso editorial (revisión), estos pueden ser depositados por parte de los autores, si estan de acuerdo, en SciELO preprints, siendo actualizados por los autores al concluir el proceso de revisión y las pruebas de maquetación.